Is This A Lemon?

Year · Make · Model

1988 Crown Coach School BUS

What the National Highway Traffic Safety Administration knows about this vehicle: every recall, every consumer complaint, every defect investigation, every NCAP crash test. Sourced directly from NHTSA data feeds.

1
Open recalls
0
NHTSA complaints
2
Defect investigations
0
Service bulletins

Recalls

1 campaign
94V237000·STRUCTURE:BODY1994-11-28

FLOOR DETERIORATION DUE TO WATER SEEPAGE.

RiskFLOOR DETERIORATION CAN CAUSE THE FLOOR TO COLLAPSE, WHICH COULD RESULT IN INJURY TO PASSENGERS OR OPERATORS.

FixTHE FLOORS OF ALL THE RECALLED BUSES WILL BE REPLACED. IN ADDITION, A "WATER FLOW" TEST WILL BE CONDUCTED ON ALL BUSES TO DETERMINE LEAKAGE SOURCES AND MAGNITUDE. ON THE OLD STYLE BUSES, WATER LEAKS WILL BE REMEDIED BY RESEALING THE DRIP RAIL AND FRONT COWL; AND ON NEW STYLE BUSES, RESPACING THE "RUB RAIL" AWAY FROM THE BOTTOM OF THE "WATERSHED," CREATING A 3/16 INCH GAP WHICH WILL ALLOW THE WATER TO FLOW OFF THE BUS.

NHTSA investigations

2 actions
EA94034·STRUCTURE1994-10-24 → 1994-12-08

FLOOR FAILURE

Led to recall94V237000

PE94049·STRUCTURE1994-06-23 → 1994-10-24

SCHOOL BUS FLOOR FAILURE

← home