VEHICLE DESCRIPTION: MOTOR HOMES EQUIPPED WITH AQUA-HOT HEATING SYSTEMS, MODEL 431-3 ZONE WITH ENGINE LOOP. FIBERGLASS INSULATING MATERIAL LOCATED UNDER THE BURNER HEAD ON THE FLOOR OF THE HEATER ENCLOSURE, CAN BECOME SOAKED WITH FLUIDS (ETHYLENE GLYCOL AND/OR DIESEL FUEL).
RiskIF AN ELECTRICAL SHORT OCCURS, A FIRE COULD RESULT.
FixDEALERS WILL REMOVE THE INSULATION FROM BENEATH THE DIESEL HEATING UNIT AS WELL AS FROM BEHIND THE CONTROL THERMOSTAT AND AIR-CONDITIONING HEATING ELEMENT ACCESS COVERS.