Is This A Lemon?

Year · Make · Model

2017 Altec Crane

What the National Highway Traffic Safety Administration knows about this vehicle: every recall, every consumer complaint, every defect investigation, every NCAP crash test. Sourced directly from NHTSA data feeds.

3
Open recalls
0
NHTSA complaints
0
Defect investigations
1
Service bulletins

Recalls

5 campaigns
20V034000·EQUIPMENT2020-01-22

Altec Industries Inc. (Altec) is recalling certain 2015-2019 Altec AC26, AC28, AC30, and AC38 Crane Aerial Devices. The boom lift cylinder hose may have been connected to a port that does not have an internal velocity fuse. Failure of a boom lift cylinder hose that is not protected by a velocity fuse can result in uncontrolled boom movement.

RiskUncontrolled movement of the boom lift increases the risk of injury.

FixAltec will notify owners and will inspect the hose to verify that it is connected properly, repairing it as necessary, free of charge. The recall began January 30, 2020. Owners may contact Altec customer service at 1-877-462-5832. Altec's number for this recall is MAB 748.

18V791000·ELECTRICAL SYSTEM:WIRING:FUSES AND CIRCUIT BREAKERS2018-11-09

Altec Industries, Inc. (Altec) is recalling certain 2008-2018 Altec AC18, AC23, AC26, AC30 and AC38 Cranes and D2B, D3A, D4A/B, DL42B, DT65 and DT80 Digger Derrick vehicles. The wiring on the 12V circuit from the chassis battery to the Power Distribution Module (PDM) may be insufficiently sized.

RiskThe insufficiently sized wire may overheat, increasing the risk of fire.

FixAltec will notify owners, and dealers will replace the wiring to the PDM, with a larger wire and/or replace the circuit breaker, free of charge. The recall began January 9, 2019. Owners may contact Altec customer service at 1-877-462-5832. Altec's number for this recall is CSN 703.

18V791000·ELECTRICAL SYSTEM:12V/24V/48V BATTERY:CABLES2018-11-09

Altec Industries, Inc. (Altec) is recalling certain 2008-2018 Altec AC18, AC23, AC26, AC30 and AC38 Cranes and D2B, D3A, D4A/B, DL42B, DT65 and DT80 Digger Derrick vehicles. The wiring on the 12V circuit from the chassis battery to the Power Distribution Module (PDM) may be insufficiently sized.

RiskThe insufficiently sized wire may overheat, increasing the risk of fire.

FixAltec will notify owners, and dealers will replace the wiring to the PDM, with a larger wire and/or replace the circuit breaker, free of charge. The recall began January 9, 2019. Owners may contact Altec customer service at 1-877-462-5832. Altec's number for this recall is CSN 703.

18V708000·ELECTRICAL SYSTEM:SOFTWARE2018-10-09

Altec Industries Inc. (Altec) is recalling certain 2014-2018 Altec AC40-152S Cranes. On the affected cranes, the electronic Load Moment and Area Protection (LMAP) screen may display incorrect load chart values.

RiskUsing an incorrect chart value could lead to unit instability or loss of load control, increasing the risk of injury.

FixAltec will notify owners, and dealers will update the LMAP software, as necessary, free of charge. The recall is expected to begin on December 4, 2018. Owners may contact Altec at 1-205-991-7733. Altec's number for this recall is CSN 696.

18V708000·ELECTRICAL SYSTEM: INSTRUMENT CLUSTER/PANEL2018-10-09

Altec Industries Inc. (Altec) is recalling certain 2014-2018 Altec AC40-152S Cranes. On the affected cranes, the electronic Load Moment and Area Protection (LMAP) screen may display incorrect load chart values.

RiskUsing an incorrect chart value could lead to unit instability or loss of load control, increasing the risk of injury.

FixAltec will notify owners, and dealers will update the LMAP software, as necessary, free of charge. The recall is expected to begin on December 4, 2018. Owners may contact Altec at 1-205-991-7733. Altec's number for this recall is CSN 696.

← home